maintain separation per plant wiring standards
500 kohm or more (power off) Output Current 25 mA Power Supply 24 VDC Power Consumption 3 W Operating Temperature -40 degC to +85 degC Ingress Protection IP66 Dimensions 35 mm (W) x 110 mm (H) x 58 mm (D) Weight Approx
Module seating must be fully engaged into the backplane connector to guarantee stable communication with the CENTUM VP or ProSafe-RS I/O subsystem
100–120 V AC input /CU2T Basic software license/tag or specific terminal/cable interface variant /NDEL No explosion protection
Communication Protocols: Supports standard industrial communication protocols for network integration
Bently Nevada 108000-02 ADRE 108 Data Acquisition Instrument Current/Voltage Input Module maintain separation per plant wiringBently Nevada 108000 02 ADRE 108 Data Acquisition Instrument Configured for vibration diagnostics, predictive maintenance, and real time monitoring of rotating machinery in ADRE platform, the Bently Nevada 108000 02 (ADRE 108 Data Acquisition Instrument) provides direct physical electrical execution of multi channel signal acquisition and digitization across sensor inputs including vibration, displacement, temperature, and process signals. Suffix